Electronic Tension Calibrator

Black

SKU: T185

€49.90
Price Alert
The Electronic Tension Calibrator makes testing the tension of your machine very easy. Perfect for calibrating electronic or manual stringing machines. Can be set to pounds or kilograms.
Share
  • Function

The T185 Electronic Tension Calibrator is a tension measurement tool used to test whether the stringing machine motor is accurate or needs tobecalibrated.

  • Key button and charging port description

ON/OFF: For power on / offThis button has "Clear / Tare”function, too.In the power-on state, tap ON / OFF to clear / tare.Clear:Zeroing Tare:Forced to Zeroing. A term used for measuring instruments,to force start from zero.KG/LB: Selection of measurement units CHG: For charging

  • Measurement operation

3.1Start-up and return to zero:In off-state, make sure that the both hooks have no strings and are in a free state. Tap ON / OFF, the screen will light up, after about 2 seconds will return to zero, displaying 0.00KG or 0.00LB

3.2Unit selection: Click KG / LB, the unit will switchbetween KG-LB. The selected unit is automatically saved and does not need to be reset at the next boot. The tension calibrator should be set to the same as tension headmotor either KG or LB.

3.3aPulling stringpreparation:Fix a string at each hook. The larger hook of the calibrator is fixed to the clamp, and locked. See as follows:ClampLarger hookShow zero String is relaxed

3.3b Pulling the string:Connect the smaller hook of the calibrator into the gripper and start to pullstring. After reach to the setting value, calibrator and motor display show their tension data. See as follows:ClampCalibrator TENSION String in gripper,string is tight

3.3c Accuracy evaluation:Please makesure that the calibrator and the motor use the same unit (both are KG or both are LB).The calibrator is dynamically displayed in real time.

Please note: pro’s pro®tension heads areequipped with a constant force pulling function. Its tension value is displayed dynamically, but it has a constant force allowable error range (such as ± 0.3LB). Within the set range, constant force maintenance adjustment is not activated and displayed. The value remains the same for better stringing experience.Therefore, the indication of calibrator and the indication of motor cannot be completely synchronizedand it is necessary to observe for a few seconds to determine the difference between the indication of calibrator and the indication of motor.Then determine whether the tension of the motor is accurate (motor allowable error range such as ± 0.3LB).

  • Shut down

4.1When thecalibrator is on, press and hold the ON / OFF key for two seconds to turn it off.

4.2 In the relaxed state where the calibrator is not pulling string, it will close automatically in 5 minutes.

4.3 In the case of calibrator‘s tension data alreadystable, it will automatically shut down in 3 minutes.

  • Charge

OurElectronic Tension Calibrator is equipped with a rechargeable 3.7V lithium battery and can be charged using any standard USB port with +5DC.The orange (red) indicator is on, indicating charging status. The green light is on, indicating that charging is complete.Charging status, orange (red) light is on.